CRC18/CRR18
18 SEER/2-5 Tons
SPLIT SYSTEM CONDENSING UNIT
24,000-60,000 Btu/h Cooling Capacity
HIGH PERFORMANCE SERIES IIR410A/GREEN PRODUCTSII
DESIGN FEATURES: 
- Oval coil design suppresses flow recirculation, separation and corner singularities for high energy efficiency+
- R-410A Environment friendly refrigerant
- Energy-efficient single and two-stage Scroll compressors
- High performance PSC and ECM motors
- Rifled copper tube/enhanced aluminum Lanced fin
- High and low pressure switches for equipment protection
- Equipped with Emerson Comfort Alert Diagnosis
- Powdered coated cabinet to prevent rust
- Easy access to covered and protected service valves
- Sound level in 70-75 dBA range with compressor blanket
- Conform to AHRI/ASHRAE Standards
- Meet Energy-Star ratings
CONDENSING UNIT NOMENCLATURE
CR | C | 18 | 060 | C | A | 1 | 1 | 1 | 1 |
Product Type | Cabinet Configuration | Unit Efficiency | Unit Capacity | Operating Mode | Series Revision | Compressor Type | Condenser Motor Type | Throttling Device | Voltage |
Product Type
CR = Condensing Unit for Residential Split System
Cabinet Configuration
C = Circular Oval
R = Rectangular
Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER
Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)
Operating Mode
C = Cool Only
H = Heat Pump
Series Revision
Coil Configuration, etc.
(Contact Manufacturer)
CR = Condensing Unit for Residential Split System
Cabinet Configuration
C = Circular Oval
R = Rectangular
Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER
Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)
Operating Mode
C = Cool Only
H = Heat Pump
Series Revision
Coil Configuration, etc.
(Contact Manufacturer)
Compressor Type
1 – R410 Single Stage (1 Speed) Copeland Scroll Compressor
2 – R410 Two Stage (2 Speeds) Copeland Scroll Compressor
3 – R410 Digital (Variable Speeds) Copeland Scroll Compressor
Condenser Motor Type
1 = PSC, GE
2 = ECM, GE
Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve
Voltage Type
1 – 208/230 V, 1 Ph., 60 Hz.
2 – 208/230 V, 1 Ph., 50 Hz.
3 – 208/230 V, 3 Ph., 60 Hz.
4 – 480 V, 3 Ph., 60 Hz.
5 – 460/230 V, 3 Ph., 60 Hz.
6 – 380/415 V, 3 Ph., 50 Hz.
7 – 575V, 3 Ph., 60Hz
1 – R410 Single Stage (1 Speed) Copeland Scroll Compressor
2 – R410 Two Stage (2 Speeds) Copeland Scroll Compressor
3 – R410 Digital (Variable Speeds) Copeland Scroll Compressor
Condenser Motor Type
1 = PSC, GE
2 = ECM, GE
Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve
Voltage Type
1 – 208/230 V, 1 Ph., 60 Hz.
2 – 208/230 V, 1 Ph., 50 Hz.
3 – 208/230 V, 3 Ph., 60 Hz.
4 – 480 V, 3 Ph., 60 Hz.
5 – 460/230 V, 3 Ph., 60 Hz.
6 – 380/415 V, 3 Ph., 50 Hz.
7 – 575V, 3 Ph., 60Hz
CONDENSING UNIT SPECIFICATIONS
MODELS: | CRC18024 CRR18024 |
CRC18030 CRR18030 |
CRC18036 CRR18036 |
CRC18042 CRR18042 |
CRC18048 CRR18048 |
CRC18060 CRR18060 |
UNIT CAPACITY | ||||||
Nominal Cooling (Btu/h) | 24,000 | 30,000 | 36,000 | 42,000 | 48,000 | 60,000 |
SEER | UP TO 18 SEER | |||||
Compressor | COPELAND SCROLL | |||||
RLA | 11.7 | 13.1 | 15.3 | 17.9 | 21.2 | 27.1 |
LRA | 58.3 | 73.0 | 83.0 | 96.0 | 104.0 | 152.9 |
REFRIGERATION SYSTEM | ||||||
Refrigerant Type | R-410A | |||||
Refrigerant Line Set: | ||||||
Liquid Line Diameter | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” |
Suction Line Diameter | 3/4” | 3/4” | 3/4” | 7/8” | 7/8” | 7/8” |
Discharge Line Diameter | 1/2” | 1/2” | 1/2” | 1/2” | 1/2” | 1/2” |
ThrottlingDevice | TXV | |||||
TXV Size | 2 Ton | 2 Ton | 3 Ton | 3 Ton | 4 Ton | 5 Ton |
Liquid Valve Connection | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” |
Suction Valve Connection | 3/4” | 3/4” | 3/4” | 7/8” | 7/8” | 7/8” |
Refrigerant Charge++ (lbs.) | 6.56 | 6.68 | 11.16 | 11.45 | 13.20 | 13.88 |
CONDENSER FAN MOTOR | ||||||
Rated HP | 1/5:1/3 | 1/5:1/3 | 1/5:1/3 | 1/5:1/3 | 1/5:1/3 | 1/5:1/3 |
RPM, Low/High Speed | 645/802 | 649/813 | 647/826 | 644/842 | 719/849 | 721/851 |
Air-flow, Low/High SCFM | 3120/3723 | 3132/3730 | 3209/3890 | 3192/3878 | 4139/4627 | 4156/4625 |
Rated FLA | 2.80 | 2.80 | 2.80 | 2.80 | 2.80 | 2.80 |
CONDENSER COIL^ | ||||||
Model Number (Contact Manufacturer) | CR401102426 | CR401102426 | CR401102427 | CR421102427 | CR421102228 | CR421102229 |
Face Area, Sq. Ft. | 30.56 | 30.56 | 30.56 | 32.08 | 32.08 | 32.08 |
ELECTRICAL DATA | ||||||
Voltage/Phase-Hz | 208/230/1-60 | 208/230/1-60 | 208/230/1-60 | 208/230/1-60 | 208/230/1-60 | 208/230/1-60 |
MCA/MOP** | 17.4/25 | 19.3/30 | 21.9/35 | 25.2/40 | 29.3/50 | 36.7/60 |
SOUND POWER (dBA) | 70.7/71.1 | 70.6/71.3 | 71.2/71.8 | 72.1/73.2 | 74.7/75.2 | 75.0/75.6 |
MODELS | CRC18024 | CRC18030 | CRC18036 | CRC18042 | CRC18048 | CRC18060 |
INSTALLED/SHIPPING WEIGHT+ | 303/318 | 303/318 | 306/321 | 341/361 | 341/361 | 345/365 |
MODELS | CRR18024 | CRR18030 | CRR18036 | CRR18042 | CRR18048 | CRR18060 |
INSTALLED/SHIPPING WEIGHT+ | 325/340 | 325/340 | 328/343 | 365/385 | 365/385 | 369/389 |
+in lbs.
^ Condenser Coil Configuration (Contact Manufacturer)
++Unit Full Charge includes 25Ft of Liquid and Suction Line Set.
**Minimum Circuit Ampacity/Maximum Overcurrent Protection
DIMENSIONS:

MODELS | DIMENSIONS* | ||
L | W | H | |
CRC18024 | 46.60 | 40.50 | 40.25 |
CRR18024 | 41.25 | 40.50 | 40.25 |
CRC18030 | 46.60 | 40.50 | 40.25 |
CRR18030 | 41.25 | 40.50 | 40.25 |
CRC18036 | 46.60 | 40.50 | 40.25 |
CRR18036 | 41.25 | 40.50 | 40.25 |
CRC18042 | 46.60 | 40.50 | 42.25 |
CRR18042 | 41.25 | 40.50 | 42.25 |
CRC18048 | 46.60 | 40.50 | 42.25 |
CRR18048 | 41.25 | 40.50 | 42.25 |
CRC18060 | 46.60 | 40.50 | 42.25 |
CRR18060 | 41.25 | 40.50 | 42.25 |
*Inches
AHRI 210/240 STANDARD RATINGS
OUTDOOR UNIT SERIES | INDOOR UNIT SERIES | COOLING CAPACITY | ENERGY EFFICIENCY | INDOOR (CFM) HIGH/LOW | ||||
OUTDOOR UNIT MODEL | OUTDOOR COIL MODEL | INDOOR UNIT MODEL | INDOOR COIL MODEL | TOTAL CAPACITY | S.H.R** | EER^ | SEER^^ | |
CRC18024*2211 CRR18024*2211 |
CR401102426 | AHRC18024*** AHRR18024*** |
AH16221634 AH16221636 AH16221638+ |
25250 | 0.69 | 13.52 | 18.09 | 759/607 |
CRC18030*2211 CRR18030*2211 |
CR401102426 | AHRC18030*** AHRR18030*** |
AH16221634 AH16221636 AH16221638+ |
33513 | 0.71 | 13.23 | 17.88 | 929/745 |
CRC18036*2211 CRR18036*2211 |
CR401102427 | AHRC18036*** AHRR18036*** |
AH16261634 AH16261636 AH16261638+ |
38557 | 0.73 | 13.35 | 17.95 | 1175/940 |
CRC18042*2211 CRR18042*2211 |
CR421102427 | AHRC18042*** AHRR18042*** |
AH16261634 AH16261636 AH16261638+ |
43437 | 0.70 | 13.37 | 17.87 | 1352/1082 |
CRC18048*2211 CRR18048*2211 |
CR421102228 | AHRC18048*** AHRR18048*** |
AH16301634 AH16301636 AH16301638+ |
49625 | 0.68 | 13.51 | 17.97 | 1450/1160 |
CRC18060*2211 CRR18060*2211 |
CR421102229 | AHRC18060*** AHRR18060*** |
AH16301634 AH16301636 AH16301638+ |
60175 | 0.70 | 13.36 | 17.62 | 1805/1444 |
**S.H.R. = Sensible Heat Ratio
+Indoor Coil Used for the Rating
^Energy Efficiency Ratio