AHRC14/AHRR14 Design Features

SPLIT SYSTEM AIR HANDLING UNIT
HIGH PERFORMANCE AIR HANDLING UNIT WITH AN IMPENETRABLE INTERNAL METAL LINING DESIGN++

  • Circular Cabinet Design of continuous curvature suppresses flow corner singularities and eddies for higher energy efficiency++
  • Insulated double walls in cylindrical and rectangular cabinets reduce energy Losses; sound power level and air leakage rate to ASHRAE standards.
  • Inner sheet metal wall lining prevents airflow contacts with fiberglass insulation and dust particles for high Indoor Air Quality (IAQ)
  • Designed specifically for high IAQ requirements in Homes, Schools, Healthcare facilities and Government/Public Offices.
  • Equipped with Thermostatic Expansion Valve (TXV), Transformer, Time-delay; and direct drive programmable ECM motors for efficient operation
  • Carefully rated heating elements for comfortable room temperatures
  • Direct Expansion coils are designed with rifled tubing, louvered surface and rippled Edge aluminum fins for high energy efficiency
  • Powder-coated pre-painted cabinet for rust-free appearance
  • All copper joints are sweat connections to prevent refrigerant leaks
  • Several electrical knockouts provided for direct access to power supply and low-voltage lines
  • Mounting tracks provide easy installation and removal of evaporator coil
  • Multi-position cabinet installation with support brackets for circular cabinet
  • Removable sliding filter-racks for easy access for installation and removal of air filters
  • Capacity and Efficiency based designs
  • Meet AHRI and ASHRAE Standards and conform to ETL Testing Standards

NOMENCLATURE

AHR C 14 030 A A V 1 1 1 1 00
Product Type Cabinet Configuration Efficiency Unit Capacity Coil Arrangement Series Revision Cabinet Orientation Evaporator Motor Type Refrigerant Type Throttling Device Voltage Heating Size
Product Type
AHR = Air Handling Unit for Residential Split System

Cabinet Configuration
C = Circular
R = Rectangular

Matching Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER

Matching Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)

Coil Arrangement
A = A-Coil
P = Parallel Slabs (Tandem)
C = Circular Coil

Series Revision
A = Revision A (Coil Configuration, etc.)
(Contact Manufacturer)
Cabinet Orientation
V = Vertical
H = Horizontal
M = Multi-Position

Evaporator Motor Type
1 = PSC, GE
2 = ECM, GE

Refrigerant Type
1 = R-410A
2 = R-22

Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve

Voltage
1 = 208/230 V, 1Ph., 60 Hz.
2 = 208/230 V, 1Ph., 50 Hz.

Heating Size
00 = No Heat
03 = 3kW
04 = 4kW
05 = 5kW
10 = 10kW
12 = 12.5kW
15 = 15kW
17 = 17.5kW
20 = 20kW
25 = 25kW

 

AIR HANDLING UNIT SPECIFICATIONS

MODEL AHRC14024
AHRR14024
AHRC14030
AHRR14030
AHRC14036
AHRR14036
AHRC14042
AHRR14042
AHRC14048
 AHRR14048
AHRC14060
AHRR14060
Nominal Cooling Capacity, Btu/h 24,000 30,000 36,000 42,000 48,000 60,000
Evaporator Coil Refrigerant Type: 2 Ton 2 Ton 3-Ton 3-Ton 4 Ton 5-Ton
TXV Size (A/C & HP) R-410A R-410A R-410A R-410A R-410A R-410A
Coil Model Number (Contact Manufacturer) AH16221636 AH16221636 AH16261636 AH16261636 AH16301636 AH16301636
Total Face Area (Sq.Ft.) 4.89 4.89 5.78 5.78 6.67 6.67
Coil Arrangements (Contact Manufacturer): A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
Refrigerant Line Set:
Liquid Line Size 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Suction Line Size 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
Blower and Motor:
Blower Wheel Width 7 1/8” 7 1/8” 8” 8” 10 5/8” 10 5/8”
Blower Wheel Diameter 9 1/2” 9 1/2” 9 1/2” 9 1/2” 12 1/4” 12 1/4”
Housing Discharge 9 3/16” x 10 1/4” 9 3/16” x 10 1/4” 10 ½” x 11 3/8” 10 ½” x 11 3/8” 13 3/16” x 13 5/8” 13 3/16” x 13 5/8”
Blower Motor, FLA/HP 3.5/ 1/2 3.5/ 1/2 3.5/ 1/2 3.5/ 1/2 4.6/ 3/4 4.6/ 3/4
Rated Voltage (@60Hz) 208/230 208/230 208/230 208/230 208/230 208/230
SCFM RANGE Low-High
(i) Nominal Cool/heat: 600-800 700-1000 850-1200 900-1400 900-1600 1400-2000
(ii) Dehumidification: 419-600 419-750 639–900 842-1000 875-1200 1027-1400
Electric Heater, kW* 10 12.5 15 17.5 20 25
MCA/MOP** 208V
230V
49.5/50
54.4/60
60.7/70
66.9/70
72.0/80
79.4/80
83.3/90
91.9/100
95.9/100
105.8/110
117.0/25
129.4/150
Cabinet Size(AHRCA): AHRC14024 AHRC14030 AHRC14036 AHRC14042 AHRC14048 AHRC14060
Air Discharge Opening 11” x 15 3/8” 11” x 15 3/8” 11” x 19 1/4” 11” x 19 1/4” 13 1/2 x 22” 13 1/2 x 22”
Cabinet Diameter++ 27 1/2” 27 1/2” 27 1/2” 27 1/2” 27 1/2” & 33” 27 1/2” & 33”
Cabinet Height 49 1/4” 49 1/4” 53 1/4” 53 1/4” 59 7/8” 59 7/8”
Installed/Shipping Weight ( in lbs.) 206/221 206/221 234/249 234/249 300/320 300/320
Cabinet Size(AHRRA): AHRR14024 AHRR14030 AHRC14036 AHRC14042 AHRC14048 AHRC14060
Air Discharge Opening 11” x 15 3/8” 11” x 15 3/8” 11” x 19 1/4” 11” x 19 1/4” 13 1/2 x 22” 13 1/2 x 22”
Cabinet Length (Side) 21” 21” 21” 21” 21 7/8” 21 7/8”
Cabinet Width (Front) 22” 22” 22” 22” 25 1/2” 25 1/2”
Cabinet Height 49 1/4” 49 1/4” 53 1/4” 53 1/4” 59 7/8” 59 7/8”
Installed/Shipping Weight ( in lbs.) 165/177 165/177 200/215 200/215 260/277 260/277

*See heater sizing; **Min. Circuit Ampacity/Max. Overcurrent Protection (Heater & Blower Motor Amps); ++Subject to Revision

DIMENSIONS:

MODEL DIMENSIONS+
D H
AHRC14024 27 1/2 49 1/4
AHRC14030 27 1/2 49 1/4
AHRC14036 27 1/2 53 1/4
AHRC14042 27 1/2 53 1/4
AHRC14048 27 ½ &33 59 7/8
AHRC14060 27 ½ &33 59 7/8
MODEL DIMENSIONS+
L W H
AHRR14024 21 22 49 1/4
AHRR14030 21 22 49 1/4
AHRR14036 21 22 53 1/4
AHRR14042 21 22 53 1/4
AHRR14048 21 7/8 25 1/2 59 7/8
AHRR14060 21 7/8 25 1/2 59 7/8

+Dimensions in inches

AHRI 210/240 STANDARD RATINGS

OUTDOOR UNIT SERIES INDOOR UNIT SERIES COOLING CAPACITY ENERGY EFFICIENCY INDOOR (CFM)
OUTDOOR UNIT MODEL OUTDOOR COIL MODEL INDOOR UNIT MODEL  INDOOR COIL MODEL TOTAL CAPACITY S.H.R**
EER SEER
CRC14024*1111
CRR14024*1111
CR361002413 AHRC14024***
AHRR14024***
AH16221634
AH16221636+
AH16221638
23720 0.72 11.78 14.20 792
CRC14030*1111
CRR14030*1111
CR361002413 AHRC14030***
AHRR14030***
AH16221634
AH16221636+
AH16221638
28865 0.68 11.74 14.08 995
CRC14036*1111
CRR14036*1111
CR361052414 AHRC14036***
AHRR14036***
AH16261634
AH16261636+
AH16261638
35859 0.70 11.66 14.33 1188
CRC14042*1111
CRR14042*1111
CR361052414 AHRC14042***
AHRR14042***
AH16261634
AH16261636+
AH16261638
41825 0-72 12.10 14.28 1393
CRC14048*1111
CRR14048*1111
CR401102216 AHRC14048***
AHRR14048***
AH16301634
AH16301636+
AH16301638
47952 0.70 11.39 14.19 1568
CRC14060*1111
CRR14060*1111
CR401102218 AHRC14060***
AHRR14060***
AH16301634
AH16301636+
AH16301638
58721 0.69 11.18 14.21 1875

**S.H.R. = Sensible Heat Ratio +Indoor Coil Used for the Rating ^Energy Efficiency Ratio ^^Seasonal Energy Efficiency Ratio