AHRC15/AHRR15 Design Features

SPLIT SYSTEM AIR HANDLING UNIT
HIGH PERFORMANCE AIR HANDLING UNIT WITH AN IMPENETRABLE INTERNAL METAL LINING DESIGN++

  • Circular Cabinet Design of continuous curvature suppresses flow corner singularities and eddies for higher energy efficiency++
  • Insulated double walls in cylindrical and rectangular cabinets reduce energy Losses; sound power level and air leakage rate to ASHRAE standards.
  • Inner sheet metal wall lining prevents airflow contacts with fiberglass insulation and dust particles for high Indoor Air Quality (IAQ)
  • Designed specifically for high IAQ requirements in Homes, Schools, Healthcare facilities and Government/Public Offices.
  • Equipped with Thermostatic Expansion Valve (TXV), Transformer, Time-delay; and direct drive programmable ECM motors for efficient operation
  • Carefully rated heating elements for comfortable room temperatures
  • Direct Expansion coils are designed with rifled tubing, louvered surface and rippled Edge aluminum fins for high energy efficiency
  • Powder-coated pre-painted cabinet for rust-free appearance
  • All copper joints are sweat connections to prevent refrigerant leaks
  • Several electrical knockouts provided for direct access to power supply and low-voltage lines
  • Mounting tracks provide easy installation and removal of evaporator coil
  • Multi-position cabinet installation with support brackets for circular cabinet
  • Removable sliding filter-racks for easy access for installation and removal of air filters
  • Capacity and Efficiency based designs
  • Meet AHRI and ASHRAE Standards and conform to ETL Testing Standards

NOMENCLATURE

AHR C 15 036 A A V 1 1 1 1 00
Product Type Cabinet Configuration Efficiency Unit Capacity Coil Arrangement Series Revision Cabinet Orientation Evaporator Motor Type Refrigerant Type Throttling Device Voltage Heating Size
Product Type
AHR = Air Handling Unit for Residential Split System

Cabinet Configuration
C = Circular
R = Rectangular

Matching Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER

Matching Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)

Coil Arrangement
A = A-Coil
P = Parallel Slabs (Tandem)
C = Circular Coil

Series Revision
A = Revision A (Coil Configuration, etc.)
(Contact Manufacturer)
Cabinet Orientation
V = Vertical
H = Horizontal
M = Multi-Position

Evaporator Motor Type
1 = PSC, GE
2 = ECM, GE

Refrigerant Type
1 = R-410A
2 = R-22

Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve

Voltage
1 = 208/230 V, 1Ph., 60 Hz.
2 = 208/230 V, 1Ph., 50 Hz.

Heating Size
00 = No Heat
03 = 3kW
04 = 4kW
05 = 5kW
10 = 10kW
12 = 12.5kW
15 = 15kW
17 = 17.5kW
20 = 20kW
25 = 25kW

 

AIR HANDLING UNIT SPECIFICATIONS

MODEL AHRC15024
AHRR15024
AHRC15030
AHRR15030
AHRC15036
AHRR15036
AHRC15042
AHRR15042
AHRC15048
AHRR15048
AHRC15060
AHRR15060
Nominal Cooling Capacity, Btu/h 24,000 30,000 36,000 42,000 48,000 60.000
Evaporator Coil Refrigerant Type: R-410A R-410A R-410A R-410A R-410A R-410A
TXV Size (A/C & HP): 2 Ton 2 Ton 3 Ton 3 Ton 4 Ton 5 Ton
Coil Model Number (Contact Manufacturer): AH16221636 AH16221636 AH16261636 AH16261636 AH16301636 AH16301636
Total Face Area (Sq.Ft.): 4.89 4.89 5.78 5.78 6.67 6.67
Coil Arrangements:(Contact Manufacturer): A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
A
TANDEM
CIRCULAR
Refrigerant Line Set:
Liquid Line Size: 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Suction Line Size: 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
Blower and Motor:
Blower Wheel Width: 7 1/8” 7 1/8” 8” 8” 10 5/8” 10 5/8”
Blower Wheel Diameter: 9 1/2” 9 1/2” 9 1/2” 9 1/2” 12 1/4” 12 1/4”
Housing Discharge: 9 3/16” x 10 1/4” 9 3/16” x 10 1/4” 10 ½” x 11 3/8” 10 ½” x 11 3/8” 13 3/16” x 13 5/8” 13 3/16” x 13 5/8”
Blower Motor, FLA/HP: 3.5/ 1/2 3.5/ 1/2 3.5/ 1/2 3.5/ 1/2 4.6/ 3/4 4.6/ 3/4
Rated Voltage (@60Hz): 208/230 208/230 208/230 208/230 208/230 208/230
SCFM RANGE High-Low:
(i) Nominal Cool/heat: 600-800 700-1000 850-1200 900-1400 900-1600 1400-2000
(ii) Dehumidification: 419-600 419-750 639–900 842-1000 875-1200 1027-1400
Electric Heater, Kw*: 10 12.5 15 17.5 20 25
MCA/MOP** 208V
MCA/MOP** 230V
49.5/50
54.4/60
60.7/70
66.9/70
72.0/80
79.4/80
83.3/90
91.9/100
95.9/100
105.8/110
117.0/25
129.4/150
Cabinet Size(AHRCA) AHRC15024 AHRC15030 AHRC15036 AHRC15042 AHRC15048 AHRC15060
Air Discharge Opening: 11” x 15 3/8” 11” x 15 3/8” 11” x 19 1/4” 11” x 19 1/4” 13 1/2″ x 22” 13 1/2″ x 22”
Cabinet Diameter 27 1/2” 27 1/2” 27 1/2” 27 1/2” 27 1/2” & 33” 27 1/2” & 33”
Cabinet Height 49 1/4” 49 1/4” 53 1/4” 53 1/4” 59 7/8” 59 7/8”
Installed/Shipping Weight 206/221 206/221 234/249 234/249 300/320 300/320
Cabinet Size(AHRRA): AHRR15024 AHRR15030 AHRR15036 AHRR15042 AHRR15048 AHRR15060
Air Discharge Opening 11” x 15 3/8” 11” x 15 3/8” 11” x 19 1/4” 11” x 19 1/4” 13 1/2″ x 22” 13 1/2″ x 22”
Cabinet Length (Side) 21” 21” 21” 21” 21 7/8” 21 7/8”
Cabinet Width (Front) 22” 22” 22” 22” 25 1/2” 25 1/2”
Cabinet Height 49 1/4” 49 1/4” 53 1/4” 53 1/4” 59 7/8” 59 7/8”
Installed/Shipping Weight 165/177 165/177 200/215 200/215 260/277 260/277

*See heater sizing; **Min. Circuit Ampacity/Max. Overcurrent Protection (Heater & Blower Motor Amps); ++Subject to Revision

DIMENSIONS

 MODEL DIMENSIONS+
D H
AHRC15024 27 1/2 49 1/4
AHRC15030 27 1/2 49 1/4
AHRC15036 27 1/2 53 1/4
AHRC15042 27 1/2 53 1/4
AHRC15048 27 ½ &33 59 7/8
AHRC15060 27 ½ &33 59 7/8
MODEL DIMENSIONS+
L W H
AHRR15024 21 22 49 1/4
AHRR15030 21 22 49 1/4
AHRR15036 21 22 53 1/4
AHRR15042 21 22 53 1/4
AHRR15048 21 7/8 25 1/2 59 7/8
AHRR15060 21 7/8 25 1/2 59 7/8

+Dimensions in inches

AHRI 210/240 STANDARD RATINGS

 

OUTDOOR UNIT SERIES INDOOR UNIT SERIES COOLING CAPACITY ENERGY EFFICIENCY INDOOR(CFM)
OUTDOOR UNIT MODEL OUTDOOR COIL MODEL INDOOR UNIT MODEL  INDOOR COIL MODEL TOTAL CAPACITY S.H.R**
EER^ SEER^^
CRC15024*1111
CRR15024*1111
CR361002416 AHRC15024***
AHRR15024***
AH16221634
AH16221636+
AH16221638
23785 0.68 12.95 15.26 782
CRC15030*1111
CRR15030*1111
CR361002416 AHRC15030***
AHRR15030***
AH16221634
AH16221636+
AH16221638
29146 0.70 13.10 15.12 980
CRC15036*1111
CRR15036*1111
CR361052418 AHRC15036***
AHRR15036***
AH16261634
AH16261636+
AH16261638
35655 0.72 13.20 15.25 1186
CRC15042*1111
CRR15042*1111
CR361052428 AHRC15042***
AHRR15042***
AH16261634
AH16261636+
AH16261638
41750 0.71 12.97 15.17 1320
CRC15048*1111
CRR15048*1111
CR361102228 AHRC15048***
AHRR15048***
AH16301634
AH16301636
AH16301638+
47615 0.69 12.63 15.21 1570
CRC15060*1111
CRR15060*1111
CR361102228 AHRC15060***
AHRR15060***
AH16301634
AH16301636
AH16301638+
59596 0.70 12.75 15.09 1850

** Sensible Heat Ratio +Indoor Coil Used for the Rating ^Energy Efficiency Ratio ^^Seasonal Energy Efficiency Ratio