AHRC16/AHRR16 Design Features
SPLIT SYSTEM AIR HANDLING UNIT
HIGH PERFORMANCE AIR HANDLING UNIT WITH AN IMPENETRABLE INTERNAL METAL LINING DESIGN++
- Circular Cabinet Design of continuous curvature suppresses flow corner singularities and eddies for higher energy efficiency++
- Insulated double walls in cylindrical and rectangular cabinets reduce energy Losses; sound power level and air leakage rate to ASHRAE standards.
- Inner sheet metal wall lining prevents airflow contacts with fiberglass insulation and dust particles for high Indoor Air Quality (IAQ)
- Designed specifically for high IAQ requirements in Homes, Schools, Healthcare facilities and Government/Public Offices.
- Equipped with Thermostatic Expansion Valve (TXV), Transformer, Time-delay; and direct drive programmable ECM motors for efficient operation
- Carefully rated heating elements for comfortable room temperatures
- Direct Expansion coils are designed with rifled tubing, louvered surface and rippled Edge aluminum fins for high energy efficiency
- Powder-coated pre-painted cabinet for rust-free appearance
- All copper joints are sweat connections to prevent refrigerant leaks
- Several electrical knockouts provided for direct access to power supply and low-voltage lines
- Mounting tracks provide easy installation and removal of evaporator coil
- Multi-position cabinet installation with support brackets for circular cabinet
- Removable sliding filter-racks for easy access for installation and removal of air filters
- Capacity and Efficiency based designs
- Meet AHRI and ASHRAE Standards and conform to ETL Testing Standards
Nomenclature
AHR | C | 16 | 042 | A | A | V | 1 | 1 | 1 | 1 | 00 |
Product Type | Cabinet Configuration | Efficiency | Unit Capacity | Coil Arrangement | Series Revision | Cabinet Orientation | Evaporator Motor Type | Refrigerant Type | Throttling Device | Voltage | Heating Size |
Product Type
AHR = Air Handling Unit for Residential Split System
Cabinet Configuration
C = Circular
R = Rectangular
Matching Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER
Matching Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)
Coil Arrangement
A = A-Coil
P = Parallel Slabs (Tandem)
C = Circular Coil
Series Revision
A = Revision A (Coil Configuration, etc.)
(Contact Manufacturer)
AHR = Air Handling Unit for Residential Split System
Cabinet Configuration
C = Circular
R = Rectangular
Matching Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER
Matching Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)
Coil Arrangement
A = A-Coil
P = Parallel Slabs (Tandem)
C = Circular Coil
Series Revision
A = Revision A (Coil Configuration, etc.)
(Contact Manufacturer)
Cabinet Orientation
V = Vertical
H = Horizontal
M = Multi-Position
Evaporator Motor Type
1 = PSC, GE
2 = ECM, GE
Refrigerant Type
1 = R-410A
2 = R-22
Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve
Voltage
1 = 208/230 V, 1Ph., 60 Hz.
2 = 208/230 V, 1Ph., 50 Hz.
Heating Size
00 = No Heat
03 = 3kW
04 = 4kW
05 = 5kW
10 = 10kW
12 = 12.5kW
15 = 15kW
17 = 17.5kW
20 = 20kW
25 = 25kW
V = Vertical
H = Horizontal
M = Multi-Position
Evaporator Motor Type
1 = PSC, GE
2 = ECM, GE
Refrigerant Type
1 = R-410A
2 = R-22
Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve
Voltage
1 = 208/230 V, 1Ph., 60 Hz.
2 = 208/230 V, 1Ph., 50 Hz.
Heating Size
00 = No Heat
03 = 3kW
04 = 4kW
05 = 5kW
10 = 10kW
12 = 12.5kW
15 = 15kW
17 = 17.5kW
20 = 20kW
25 = 25kW
AIR HANDLING UNIT SPECIFICATIONS
MODEL | AHRC16024 AHRR16024 |
AHRC16030 AHRR16030 |
AHRC16036 AHRR16036 |
AHRC16042 AHRR16042 |
AHRC16048 AHRR16048 |
AHRC16060 AHRR16060 |
Nominal Cooling Capacity, Btu/h | 24,000 | 30,000 | 36,000 | 42,000 | 48,000 | 60.000 |
Evaporator Coil Refrigerant Type: | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A |
TXV Size (A/C & HP): | 2 Ton | 2 Ton | 3 Ton | 3 Ton | 4 Ton | 5 Ton |
Coil Model Number (Contact Manufacturer): | AH16221636 | AH16221636 | AH16261636 | AH16261636 | AH16301636 | AH16301636 |
Total Face Area (Sq.Ft.): | 4.89 | 4.89 | 5.78 | 5.78 | 6.67 | 6.67 |
Coil Arrangements:(Contact Manufacturer): | A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
Refrigerant Line Set: | ||||||
Liquid Line Size: | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” |
Suction Line Size: | 3/4” | 3/4” | 3/4” | 7/8” | 7/8” | 7/8” |
Blower and Motor: | ||||||
Blower Wheel Width: | 7 1/8” | 7 1/8” | 8” | 8” | 10 5/8” | 10 5/8” |
Blower Wheel Diameter: | 9 1/2” | 9 1/2” | 9 1/2” | 9 1/2” | 12 1/4” | 12 1/4” |
Housing Discharge: | 9 3/16” x 10 1/4” | 9 3/16” x 10 1/4” | 10 ½” x 11 3/8” | 10 ½” x 11 3/8” | 13 3/16” x 13 5/8” | 13 3/16” x 13 5/8” |
Blower Motor, FLA/HP: | 3.5/ 1/2 | 3.5/ 1/2 | 3.5/ 1/2 | 3.5/ 1/2 | 4.6/ 3/4 | 4.6/ 3/4 |
Rated Voltage (@60Hz): | 208/230 | 208/230 | 208/230 | 208/230 | 208/230 | 208/230 |
SCFM RANGE High-Low: | ||||||
(i) Nominal Cool/heat: | 600-800 | 700-1000 | 850-1200 | 900-1400 | 900-1600 | 1400-2000 |
(ii) Dehumidification: | 419-600 | 419-750 | 639–900 | 842-1000 | 875-1200 | 1027-1400 |
Electric Heater, Kw*: | 10 | 12.5 | 15 | 17.5 | 20 | 25 |
MCA/MOP** 208V MCA/MOP** 230V |
49.5/50 54.4/60 |
60.7/70 66.9/70 |
72.0/80 79.4/80 |
83.3/90 91.9/100 |
95.9/100 105.8/110 |
117.0/25 129.4/150 |
Cabinet Size(AHRCA) | AHRC16024 | AHRC16030 | AHRC16036 | AHRC16042 | AHRC16048 | AHRC16060 |
Air Discharge Opening: | 11” x 15 3/8” | 11” x 15 3/8” | 11” x 19 1/4” | 11” x 19 1/4” | 13 1/2″ x 22” | 13 1/2″ x 22” |
Cabinet Diameter | 27 1/2” | 27 1/2” | 27 1/2” | 27 1/2” | 27 1/2” & 33” | 27 1/2” & 33” |
Cabinet Height | 49 1/4” | 49 1/4” | 53 1/4” | 53 1/4” | 59 7/8” | 59 7/8” |
Installed/Shipping Weight | 206/221 | 206/221 | 234/249 | 234/249 | 300/320 | 300/320 |
Cabinet Size(AHRRA): | AHRR16024 | AHRR16030 | AHRR16036 | AHRR16042 | AHRR16048 | AHRR16060 |
Air Discharge Opening | 11” x 15 3/8” | 11” x 15 3/8” | 11” x 19 1/4” | 11” x 19 1/4” | 13 1/2″ x 22” | 13 1/2″ x 22” |
Cabinet Length (Side) | 21” | 21” | 21” | 21” | 21 7/8” | 21 7/8” |
Cabinet Width (Front) | 22” | 22” | 22” | 22” | 25 1/2” | 25 1/2” |
Cabinet Height | 49 1/4” | 49 1/4” | 53 1/4” | 53 1/4” | 59 7/8” | 59 7/8” |
Installed/Shipping Weight | 165/177 | 165/177 | 200/215 | 200/215 | 260/277 | 260/277 |
*See heater sizing; **Min. Circuit Ampacity/Max. Overcurrent Protection (Heater & Blower Motor Amps); ++Subject to Revision
DIMENSIONS

MODEL | DIMENSIONS+ | |
D | H | |
AHRC16024 | 27 1/2 | 49 1/4 |
AHRC16030 | 27 1/2 | 49 1/4 |
AHRC16036 | 27 1/2 | 53 1/4 |
AHRC16042 | 27 1/2 | 53 1/4 |
AHRC16048 | 27 ½ &33 | 59 7/8 |
AHRC16060 | 27 ½ &33 | 59 7/8 |
MODEL | DIMENSIONS+ | ||
L | W | H | |
AHRR16024 | 21 | 22 | 49 1/4 |
AHRR16030 | 21 | 22 | 49 1/4 |
AHRR16036 | 21 | 22 | 53 1/4 |
AHRR16042 | 21 | 22 | 53 1/4 |
AHRR16048 | 21 7/8 | 25 1/2 | 59 7/8 |
AHRR16060 | 21 7/8 | 25 1/2 | 59 7/8 |
+Dimensions in inches
AHRI 210/240 STANDARD RATINGS
OUTDOOR UNIT SERIES | INDOOR UNIT SERIES | COOLING CAPACITY | ENERGY EFFICIENCY | INDOOR(CFM) HIGH/LOW | ||||
OUTDOOR UNIT MODEL | OUTDOOR COIL MODEL | INDOOR UNIT MODEL | INDOOR COIL MODEL | TOTAL CAPACITY | S.H.R** | |||
EER^ | SEER^^ | |||||||
CRC16024*2111 CRR16030*2111 |
CR361002415 | AHRC16024*** AHRR16024*** |
AH16221636+ AH16221634 AH16221638+ |
23645 25255 |
0.72 0.75 |
13.15 13.35 |
16.22 16.07 |
786 815/652 |
CRC16030*2111 CRR16030*2111 |
CR361002415 | AHRC16030*** AHRR16030*** |
AH16221636+ AH16221634 AH16221638+ |
28634 29651 |
0.69 0.73 |
13.26 13.10 |
16.11 16.23 |
955 1006/805 |
CRC16036*2111 CRR16036*2111 |
CR361052426 | AHRC16036*** AHRR16036*** |
AH16261636+ AH16261634 AH16261638+ |
34850 35695 |
0.70 0.71 |
12.96 13.22 |
16.16 16.26 |
1203 1188/950 |
CRC16042*2111 CRR16042*2111 |
CR361052428 | AHRC16042*** AHRR16042*** |
AH16261636+ AH16261634 AH16261638+ |
41732 42330 |
0.69 0.72 |
12.98 13.10 |
16.02 16.17 |
1395 1387/1110 |
CRC16048*2111 CRR16048*2111 |
CR401102229 | AHRC16048*** AHRR16048*** |
AH16301636+ AH16301634 AH16301638+ |
47966 48128 |
0.68 0.69 |
13.08 13.22 |
15.96 16.08 |
1585 1611/1289 |
CRC16060*2111 CRR16060*2111 |
CR401102229 | AHRC16060*** AHRR16060*** |
AH16301636+ AH16301634 AH16301638+ |
56672 58835 |
0.70 0.67 |
13.21 13.29 |
16.00 16.18 |
1969 2007/1606 |
**S.H.R. = Sensible Heat Ratio +Indoor Coil Used for the Rating ^Energy Efficiency Ratio ^^Seasonal Energy Efficiency Ratio