AHRC18/AHRR18 Design Features
SPLIT SYSTEM AIR HANDLING UNIT
HIGH PERFORMANCE AIR HANDLING UNIT WITH AN IMPENETRABLE INTERNAL METAL LINING DESIGN++
- Circular Cabinet Design of continuous curvature suppresses flow corner singularities and eddies for higher energy efficiency++
- Insulated double walls in cylindrical and rectangular cabinets reduce energy Losses; sound power level and air leakage rate to ASHRAE standards.
- Inner sheet metal wall lining prevents airflow contacts with fiberglass insulation and dust particles for high Indoor Air Quality (IAQ)
- Designed specifically for high IAQ requirements in Homes, Schools, Healthcare facilities and Government/Public Offices.
- Equipped with Thermostatic Expansion Valve (TXV), Transformer, Time-delay; and direct drive programmable ECM motors for efficient operation
- Carefully rated heating elements for comfortable room temperatures
- Direct Expansion coils are designed with rifled tubing, louvered surface and rippled Edge aluminum fins for high energy efficiency
- Powder-coated pre-painted cabinet for rust-free appearance
- All copper joints are sweat connections to prevent refrigerant leaks
- Several electrical knockouts provided for direct access to power supply and low-voltage lines
- Mounting tracks provide easy installation and removal of evaporator coil
- Multi-position cabinet installation with support brackets for circular cabinet
- Removable sliding filter-racks for easy access for installation and removal of air filters
- Capacity and Efficiency based designs
- Meet AHRI and ASHRAE Standards and conform to ETL Testing Standards
Nomenclature
AHR | C | 18 | 060 | A | A | V | 1 | 1 | 1 | 1 | 00 |
Product Type | Cabinet Configuration | Efficiency | Unit Capacity | Coil Arrangement | Series Revision | Cabinet Orientation | Evaporator Motor Type | Refrigerant Type | Throttling Device | Voltage | Heating Size |
Product Type
AHR = Air Handling Unit for Residential Split System
Cabinet Configuration
C = Circular
R = Rectangular
Matching Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER
Matching Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)
Coil Arrangement
A = A-Coil
P = Parallel Slabs (Tandem)
C = Circular Coil
Series Revision
A = Revision A (Coil Configuration, etc.)
(Contact Manufacturer)
AHR = Air Handling Unit for Residential Split System
Cabinet Configuration
C = Circular
R = Rectangular
Matching Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER
Matching Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)
Coil Arrangement
A = A-Coil
P = Parallel Slabs (Tandem)
C = Circular Coil
Series Revision
A = Revision A (Coil Configuration, etc.)
(Contact Manufacturer)
Cabinet Orientation
V = Vertical
H = Horizontal
M = Multi-Position
Evaporator Motor Type
1 = PSC, GE
2 = ECM, GE
Refrigerant Type
1 = R-410A
2 = R-22
Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve
Voltage
1 = 208/230 V, 1Ph., 60 Hz.
2 = 208/230 V, 1Ph., 50 Hz.
Heating Size
00 = No Heat
03 = 3kW
04 = 4kW
05 = 5kW
10 = 10kW
12 = 12.5kW
15 = 15kW
17 = 17.5kW
20 = 20kW
25 = 25kW
V = Vertical
H = Horizontal
M = Multi-Position
Evaporator Motor Type
1 = PSC, GE
2 = ECM, GE
Refrigerant Type
1 = R-410A
2 = R-22
Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve
Voltage
1 = 208/230 V, 1Ph., 60 Hz.
2 = 208/230 V, 1Ph., 50 Hz.
Heating Size
00 = No Heat
03 = 3kW
04 = 4kW
05 = 5kW
10 = 10kW
12 = 12.5kW
15 = 15kW
17 = 17.5kW
20 = 20kW
25 = 25kW
AIR HANDLING UNIT SPECIFICATIONS
MODEL | AHRC18024 AHRR18024 |
AHRC18030 AHRR18030 |
AHRC18036 AHRR18036 |
AHRC18042 AHRR18042 |
AHRC18048 AHRR18048 |
AHRC18060 AHRR18060 |
Nominal Cooling Capacity, Btu/h | 24,000 | 30,000 | 36,000 | 42,000 | 48,000 | 60.000 |
Evaporator Coil Refrigerant Type: | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A |
TXV Size (A/C & HP): | 2 Ton | 2 Ton | 3 Ton | 3 Ton | 4 Ton | 5 Ton |
Coil Model Number (Contact Manufacturer): | AH16221636 | AH16221636 | AH16261636 | AH16261636 | AH16301636 | AH16301636 |
Total Face Area (Sq.Ft.): | 4.89 | 4.89 | 5.78 | 5.78 | 6.67 | 6.67 |
Coil Arrangements:(Contact Manufacturer): | A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
A TANDEM CIRCULAR |
Refrigerant Line Set: | ||||||
Liquid Line Size: | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” | 3/8” |
Suction Line Size: | 3/4” | 3/4” | 3/4” | 7/8” | 7/8” | 7/8” |
Blower and Motor: | ||||||
Blower Wheel Width: | 7 1/8” | 7 1/8” | 8” | 8” | 10 5/8” | 10 5/8” |
Blower Wheel Diameter: | 9 1/2” | 9 1/2” | 9 1/2” | 9 1/2” | 12 1/4” | 12 1/4” |
Housing Discharge: | 9 3/16” x 10 1/4” | 9 3/16” x 10 1/4” | 10 ½” x 11 3/8” | 10 ½” x 11 3/8” | 13 3/16” x 13 5/8” | 13 3/16” x 13 5/8” |
Blower Motor, FLA/HP: | 3.5/ 1/2 | 3.5/ 1/2 | 3.5/ 1/2 | 3.5/ 1/2 | 4.6/ 3/4 | 4.6/ 3/4 |
Rated Voltage (@60Hz): | 208/230 | 208/230 | 208/230 | 208/230 | 208/230 | 208/230 |
SCFM RANGE High-Low: | ||||||
(i) Nominal Cool/heat: | 600-800 | 700-1000 | 850-1200 | 900-1400 | 900-1600 | 1400-2000 |
(ii) Dehumidification: | 419-600 | 419-750 | 639–900 | 842-1000 | 875-1200 | 1027-1400 |
Electric Heater, Kw*: | 10 | 12.5 | 15 | 17.5 | 20 | 25 |
MCA/MOP** 208V MCA/MOP** 230V |
49.5/50 54.4/60 |
60.7/70 66.9/70 |
72.0/80 79.4/80 |
83.3/90 91.9/100 |
95.9/100 105.8/110 |
117.0/25 129.4/150 |
Cabinet Size(AHRCA) | AHRC18024 | AHRC18030 | AHRC18036 | AHRC18042 | AHRC18048 | AHRC18060 |
Air Discharge Opening: | 11” x 15 3/8” | 11” x 15 3/8” | 11” x 19 1/4” | 11” x 19 1/4” | 13 1/2″ x 22” | 13 1/2″ x 22” |
Cabinet Diameter | 27 1/2” | 27 1/2” | 27 1/2” | 27 1/2” | 27 1/2” & 33” | 27 1/2” & 33” |
Cabinet Height | 49 1/4” | 49 1/4” | 53 1/4” | 53 1/4” | 59 7/8” | 59 7/8” |
Installed/Shipping Weight | 206/221 | 206/221 | 234/249 | 234/249 | 300/320 | 300/320 |
Cabinet Size(AHRRA): | AHRR18024 | AHRR18030 | AHRR18036 | AHRR18042 | AHRR18048 | AHRR18060 |
Air Discharge Opening | 11” x 15 3/8” | 11” x 15 3/8” | 11” x 19 1/4” | 11” x 19 1/4” | 13 1/2″ x 22” | 13 1/2″ x 22” |
Cabinet Length (Side) | 21” | 21” | 21” | 21” | 21 7/8” | 21 7/8” |
Cabinet Width (Front) | 22” | 22” | 22” | 22” | 25 1/2” | 25 1/2” |
Cabinet Height | 49 1/4” | 49 1/4” | 53 1/4” | 53 1/4” | 59 7/8” | 59 7/8” |
Installed/Shipping Weight | 165/177 | 165/177 | 200/215 | 200/215 | 260/277 | 260/277 |
*See heater sizing; **Min. Circuit Ampacity/Max. Overcurrent Protection (Heater & Blower Motor Amps); ++Subject to Revision
DIMENSIONS

MODEL | DIMENSIONS+ | |
D | H | |
AHRC18024 | 27 1/2 | 49 1/4 |
AHRC18030 | 27 1/2 | 49 1/4 |
AHRC18036 | 27 1/2 | 53 1/4 |
AHRC18042 | 27 1/2 | 53 1/4 |
AHRC18048 | 27 ½ &33 | 59 7/8 |
AHRC18060 | 27 ½ &33 | 59 7/8 |
MODEL | DIMENSIONS+ | ||
L | W | H | |
AHRR18024 | 21 | 22 | 49 1/4 |
AHRR18030 | 21 | 22 | 49 1/4 |
AHRR18036 | 21 | 22 | 53 1/4 |
AHRR18042 | 21 | 22 | 53 1/4 |
AHRR18048 | 21 7/8 | 25 1/2 | 59 7/8 |
AHRR18060 | 21 7/8 | 25 1/2 | 59 7/8 |
+Dimensions in inches
AHRI 210/240 STANDARD RATINGS
OUTDOOR UNIT SERIES | INDOOR UNIT SERIES | COOLING CAPACITY | ENERGY EFFICIENCY | INDOOR (CFM) HIGH/LOW | ||||
OUTDOOR UNIT MODEL | OUTDOOR COIL MODEL | INDOOR UNIT MODEL | INDOOR COIL MODEL | TOTAL CAPACITY | S.H.R** | |||
EER^ | SEER^^ | |||||||
CRC18024*2211 CRR18024*2211 |
CR401102426 | AHRC18024*** AHRR18024*** |
AH16221634 AH16221636 AH16221638+ |
25250 | 0.69 | 13.52 | 18.09 | 759/607 |
CRC18030*2211 CRR18030*2211 |
CR401102426 | AHRC18030*** AHRR18030*** |
AH16221634 AH16221636 AH16221638+ |
33513 | 0.71 | 13.23 | 17.88 | 929/745 |
CRC18036*2211 CRR18036*2211 |
CR401102427 | AHRC18036*** AHRR18036*** |
AH16261634 AH16261636 AH16261638+ |
38557 | 0.73 | 13.35 | 17.95 | 1175/940 |
CRC18042*2211 CRR18042*2211 |
CR421102427 | AHRC18042*** AHRR18042*** |
AH16261634 AH16261636 AH16261638+ |
43437 | 0.70 | 13.37 | 17.87 | 1352/1082 |
CRC18048*2211 CRR18048*2211 |
CR421102228 | AHRC18048*** AHRR18048*** |
AH16301634 AH16301636 AH16301638+ |
49625 | 0.68 | 13.51 | 17.97 | 1450/1160 |
CRC18060*2211 CRR18060*2211 |
CR421102229 | AHRC18060*** AHRR18060*** |
AH16301634 AH16301636 AH16301638+ |
60175 | 0.70 | 13.36 | 17.62 | 1805/1444 |
**S.H.R. = Sensible Heat Ratio +Indoor Coil Used for the Rating ^Energy Efficiency Ratio ^^Seasonal Energy Efficiency Ratio